49б. Magnetic field and induction: current creates a field, the coil, mutual inductance, the transformer, self-induced EMF and switching spikes
In section 49а charge created an electric field, and capacitance and capacitive crosstalk grew out of it. Here is the second half of the picture: moving charge, that is current, creates a magnetic field. Out of it grow the inductance of a coil and of a loop on the board, the voltage spike when a switch interrupts relay current, the transformer and noise coupled from a neighbouring loop through the magnetic field. Every formula comes with a calculation on board values: a relay coil, a trace over ground, an STM32 pin edge.
Sources: the magnetic constant is CODATA 2022 from scipy.constants
(scipy 1.18.1, numpy 2.3.3, image stm-ml:1); copper resistivity is
1.7241·10⁻⁸ Ω·m per the IEC 60028 annealed copper standard (the document
is not on disk). The relay coil is 12 V, 30 mA, about 100 mH, as in
section 51.2. The turn-off spike is computed twice: by solving the circuit
equations in Python (script calc49b.py) and by a model in ngspice 39
(image stm-lab:1, file kick49b.cir). Loop inductances come from
formulas for wire segments, the coil from the sum of mutual inductances of
its turns. There are no hardware measurements.
What it is called in the documentation
Original Meaning magnetic flux density (B), tesla magnetic induction, tesla magnetic flux (Φ), weber magnetic flux, weber inductance, self-inductance inductance, self-induction back EMF, inductive kickback self-induced EMF, turn-off spike flyback (freewheeling) diode flyback diode TVS diode, clamp voltage clamp snubber snubber (damping RC network) mutual inductance, coupling coefficient (k) mutual inductance, coupling coefficient leakage inductance leakage inductance saturation current (Isat) saturation current eddy currents, skin effect eddy currents, skin effect current return path, loop area return path, loop area
49б.1 Current creates a field
The magnetic field is described by the flux density B, unit tesla (T). A tesla is a lot; on and near a board we deal with micro- and millitesla. The source of the field is current. The magnetic constant is μ₀ = 1.25663706127·10⁻⁶ H/m (CODATA 2022).
| What | Formula | Example | Field |
|---|---|---|---|
| long straight wire | B = μ0·I / (2π·r) |
1 A, 1 cm from the wire | 20.0 µT |
| circular turn, at the centre | B = μ0·I / (2R) |
1 A, radius 5 mm | 126 µT |
| long coil, inside | B = μ0·N·I / l |
100 turns over 20 mm, 0.1 A | 0.628 mT |
The field lines of a wire are circles around it; the field falls as 1/r. A wire bent into a turn gathers the field into the middle, and a coil of many turns adds up the fields of the turns. That is why a relay, an inductor and a transformer are coils: a strong field from a small current.
Where you see it on the board. The Earth's field is tens of microtesla (the model in section 99г uses 50 µT). A wire carrying amperes a few centimetres away gives as much — which is why a magnetometer is thrown off by power wires and why the supply and return wires are run together; the heading error is computed in section 99г.6, calibration in 99б and 99е. How a sensor turns the field into a voltage (Hall effect, magnetoresistance) is section 49е.
49б.2 Flux and inductance
Magnetic flux Φ is the field times the area it passes through; unit weber (Wb = T·m²). If a loop of N turns links flux Φ from its own current I, its inductance is
L = N·Φ / I
The unit is the henry (H). Inductance is a property of shape: how much flux a loop "catches" from its own current. It grows with the square of the number of turns (the field is N times stronger and N turns link it) and with area.
Air-core coil. 100 turns of 0.2 mm wire on a 10 mm former, winding
length 20 mm. The sum of the self-inductances of the turns and the mutual
inductances of all pairs gives 39.8 µH. Wheeler's formula for a
single-layer coil gives 40.2 µH, a difference of 0.9 %. The long-coil
formula μ0·N²·S/l gives 49.3 µH — 24 % more: the coil is only two
diameters long and the field "leaks out" at the ends. Each turn links
39.8 nWb at 0.1 A.
Relay coil from section 51.2: 12 V, 400 Ω resistance, 30.0 mA current,
inductance about 100 mH. Energy in the field — W = L·I²/2 = 45.0 µJ.
Time constant L/R = 0.250 ms. These numbers are needed in 49б.4.
A loop on the board. Pin current leaves along a trace and returns via ground; trace plus return path is one turn. The inductance of such a loop is computed from segments: each side has its own inductance, opposite sides have a mutual one with a minus sign (currents in opposite directions):
def l_rect(w, h, a):
"""Прямоугольная петля w×h из провода с эквивалентным радиусом a: частичные индуктивности сторон."""
return 2 * (m_par(w, a) + m_par(h, a)) - 2 * (m_par(w, h) + m_par(h, w))
The 0.25 mm trace is replaced by a round wire with an equivalent radius of 55.9 µm (the geometric mean distance of a thin strip).
| Loop of 0.25 mm trace | Inductance | Circle of the same area |
|---|---|---|
| 50 × 20 mm | 153 nH | 131 nH |
| 20 × 10 mm | 56.6 nH | 50.5 nH |
| 50 × 2 mm | 73.4 nH | 33.3 nH |
| 10 × 1 mm | 12.2 nH | 7.94 nH |
Loop area matters first: 50 × 2 mm has ten times less area and half the inductance of 50 × 20 mm. A narrow loop is worse than a circle of the same area — it has a lot of wire per unit of area.
With a solid ground under the trace the return current flows right under it (section 130.2), and the loop is the trace and its image in the ground. The per-length inductance of a microstrip from Hammerstad's formulas: a 0.25 mm trace 1.5 mm above ground — 7.75 nH/cm, 0.2 mm above — 3.81 nH/cm.
49б.3 Faraday's law and self-induction
When the flux through a loop changes, an EMF appears in the loop:
EMF = −dΦ/dt
The minus sign is Lenz's rule: the induced current opposes the change of flux. It does not matter why the flux changes — a magnet moves, the current in a neighbouring wire or in the loop itself changes. This is how the transformer, the generator, the inductive sensor and all magnetic interference work.
Mains pickup example. A 50 × 20 mm loop in a 50 Hz field of 1 µT amplitude gets an EMF of 0.314 µV amplitude, in 10 µT — 3.14 µV. On a board this is small; it gets dangerous where the loop area is metres of sensor cable or supply and return wires run apart.
Self-induction. If the flux comes from the loop's own current,
Φ·N = L·I, and
U = −L·dI/dt
A coil does not let the current change in a jump: to raise or lower the current takes a voltage, the larger the faster the change. This is the "inertia" of current in a converter inductor (section 58), the turn-off spike (49б.4) and ground noise on edges.
A pin edge: let 20 mA rise in 5 ns — 4.00 A/µs. Over 50 mm of path with the inductance from the formulas above:
| Current path over 50 mm | Inductance | L·dI/dt |
|---|---|---|
| trace 1.5 mm above ground | 38.7 nH | 155 mV |
| trace 0.2 mm above ground | 19.0 nH | 76.1 mV |
| no ground, return as a 50 × 20 mm loop | 153 nH | 614 mV |
This voltage drops along the current path, not on the load: "ground" at the far end of the trace jumps relative to ground at the microcontroller. Hence the decoupling rule — a capacitor at the supply pin and a short loop to ground (section 130.3) — and the demand for solid ground under fast signals.
49б.4 The spike when a coil is switched off
30 mA flows through the relay coil and the switch opens. The coil current
cannot vanish instantly, and it keeps flowing — wherever it is allowed to.
If there is nowhere, it charges the capacitance of the switch node (the
transistor output and wiring, 100 pF in the model), and the voltage rises
until all the field energy has moved into the capacitance:
U ≈ Usupply + I·√(L/C) = 958 V. The calculation with losses in the coil
gives 949 V, followed by ringing with a 19.9 µs period. In practice the
transistor breaks down earlier: it absorbs the energy in avalanche, and
repeated at every turn-off this kills it.
Protection gives the current a path and sets the voltage at which it decays. Five variants, the switch opens instantly:
| Protection | Peak at the switch | Current to 10 % | Energy in the coil | In the clamp | In the RC resistor |
|---|---|---|---|---|---|
| none | 949 V | 1.14 ms | 44.7 µJ | — | — |
| diode across the coil | 12.8 V | 0.476 ms | 40.4 µJ | — | — |
| diode + 24 V zener | 36.8 V | 0.0864 ms | 10.7 µJ | 33.1 µJ | — |
| RC 400 Ω, 0.68 µF across the coil | 12.0 V | 0.635 ms | 46.8 µJ | — | 46.7 µJ |
| 33 V clamp from switch to ground | 33.8 V | 0.0946 ms | 11.8 µJ | 50.2 µJ | — |
The ngspice model with the same elements gave the same peaks and times within 2 %. The diode parameters in both models are IS 2.52 nA, N 1.752, RS 0.568 Ω, a widely used 1N4148 model; they were not checked against a datasheet. The zener and the clamp are a voltage source with the same diode, without their own breakdown resistance.
What follows:
- A diode holds the switch at the supply plus the diode drop, but the current decays slowly: the coil sees only 0.8 V, and almost all the energy goes into its own resistance. The formula of section 51.2 gives 0.619 ms to zero; to 10 % the calculation gives 0.476 ms. The relay releases later.
- A diode with a zener kills the current 5.5 times faster: 24 V across the coil instead of 0.8, and the zener takes most of the energy. The price is 36.8 V on the switch: the transistor needs margin. After the current has ended, the remaining energy rings in the node capacitance — visible in the figure.
- A clamp across the switch is similar in time, but it burns more energy than the field held: while it conducts, the supply keeps driving current through the coil. 50.2 µJ versus 45.0 stored.
- An RC network keeps the voltage from rising above the supply if the capacitor is large enough: for 400 Ω at least 0.625 µF is needed (otherwise it rings), the calculation uses 0.68. The resistor takes the energy. Useful where a diode cannot be used — on AC; part sizes grow with energy.
A motor or a solenoid is the same, only with more energy. A motor also generates its own EMF when turning, and when braking it goes back into the supply. Choosing the switch and its protection — section 52, current decay modes in a stepper winding (slow through a diode and fast through the supply) — 57е, braking and coasting of a brushed motor — 57з, clamps on microcontroller pins — 62.9.
49б.5 Mutual inductance and the transformer
If the field of one loop passes through another, they are linked by a
mutual inductance M: current in the first induces EMF = −M·dI/dt in
the second. How completely is shown by the coupling coefficient
k = M / √(L1·L2), from 0 to 1.
Two coaxial turns of radius 10 mm made of 0.2 mm wire; the inductance of one is 62.0 nH:
| Distance between turns | M | k |
|---|---|---|
| 1 mm | 30.0 nH | 0.48 |
| 5 mm | 11.1 nH | 0.18 |
| 10 mm | 4.94 nH | 0.080 |
| 20 mm | 1.42 nH | 0.023 |
Even close together in air the coupling is under one half. That is why transformer windings sit on a common core: it gathers almost all the flux, and k approaches one.
Transformer. The voltage per turn is dΦ/dt, the same for all turns on
a common flux, so U2/U1 = N2/N1. Current goes the other way: input and
output power are the same (without losses). Imperfect coupling is the
leakage inductance L1·(1 − k²): the part of the primary not linked
to the secondary. Let it be 10 : 1, primary 1 mH, 100 V in:
| k | Output without load | Leakage |
|---|---|---|
| 0.99 | 9.90 V | 19.9 µH |
| 0.9 | 9.00 V | 190 µH |
| 0.5 | 5.00 V | 750 µH |
Leakage in a flyback converter is the same "relay coil" whose current the switch interrupts every period: hence snubbers on the switch (section 58). Isolation with a transformer — section 54.
Inductive crosstalk between loops. The aggressor is a 0.25 mm trace
with a current edge of 20 mA in 5 ns, the victim is a neighbouring trace,
both 50 mm long, the victim returning via ground under it. EMF in the
victim loop is M·dI/dt:
| Layout | Neighbours 1 mm apart | 3 mm | 10 mm |
|---|---|---|---|
| solid ground 1.5 mm below | 11.5 nH, 46.1 mV | 3.47 nH, 13.9 mV | 0.431 nH, 1.72 mV |
| solid ground 0.2 mm below | 0.742 nH, 2.97 mV | 0.0881 nH, 0.352 mV | 0.00799 nH, 0.0320 mV |
| no ground, returns 20 mm away on the outside | 23.8 nH, 95.0 mV | 14.1 nH, 56.4 mV | 5.88 nH, 23.5 mV |
The calculation is two-dimensional: the traces are taken as long compared
to the distances, the ends are ignored. Ground in the cross-section is
replaced by the image of the trace — exact for a solid plane; the check
against M' = μ0/(4π)·ln(1 + (2h/s)²) agrees to six digits.
What it shows: with ground under the traces the coupling falls with distance as a square — the magnetic field of the pair "trace and its return" dies out quickly. Without ground the loops are large, the field of a single current dies out slowly, and at 10 mm the crosstalk is 14 times stronger. How to reduce it, in order of effect:
- return path right alongside — solid ground under the signal or the return wire next to it (twisted pair); the aggressor loop area is small and its field does not reach far;
- closer ground — 0.2 mm instead of 1.5 mm gives 16 times less at 1 mm and even more at larger distances;
- distance — with ground, three times farther gives 3–11 times less;
- a small victim loop — it catches flux by area;
- a slower edge — the EMF is proportional to
dI/dt.
Capacitive crosstalk on the same traces — section 49а.5; when a trace is long compared to the edge it is a line, section 49в.
49б.6 The core, saturation, eddy currents
Ferromagnetic material. Iron and ferrites contain regions with their own magnetisation; an external field turns them, and the field inside is many times stronger than in air (relative permeability μr). A coil on a core gets the same inductance with fewer turns. But the regions can only turn up to a certain field: beyond it they are all aligned and μr falls towards one — saturation. Inductance collapses and the current grows without limit (numbers for a buck converter — section 58.2).
That is why inductors have a gap: a non-magnetic slit in the core.
Almost all the "magnetic resistance" is concentrated in it, the inductance
L ≈ μ0·N²·S/gap depends little on ferrite spread, and saturation comes at
a higher current. An example with arbitrary dimensions: 20 turns, 10 mm²
cross-section, 0.5 mm gap — 10.1 µH; if the ferrite is taken to saturate
at 0.3 T, the saturation current B·gap/(μ0·N) = 5.97 A, and the field
energy at this current is 179 µJ. The energy of an inductor is stored
precisely in the gap. The 0.3 T value here is not from a datasheet: the
real saturation current is taken from the inductor's datasheet.
Eddy currents. An alternating field induces EMF not only in the winding but in any conductor inside: the core, a shield, the wire itself. In solid metal ring currents flow and heat it — that is why transformer iron is stacked from thin insulated laminations, and at high frequencies ferrite, a poor conductor, is used.
In the wire itself eddy currents push the current to the surface — the
skin effect. The depth at which current falls by a factor of e,
δ = √(2ρ/(ω·μ0)) for copper:
| Frequency | Skin depth |
|---|---|
| 50 Hz | 9346 µm |
| 1 MHz | 66.1 µm |
| 100 MHz | 6.61 µm |
A 35 µm copper trace stops working with its full thickness from about 3.57 MHz (where δ equals the thickness). For clock frequencies and edge harmonics the trace resistance is higher than the DC value of section 49.8; an inductor at hundreds of kilohertz uses fine stranded wire.
49б.7 Pitfalls
A relay without a diode works for weeks, then the transistor dies or the board resets. With no path for the current the coil lifts the switch node to hundreds of volts: 949 V in the model. A diode across the coil — 12.8 V.
With a diode the relay releases late. The current decays through the coil resistance: 0.476 ms to 10 %. A diode with a 24 V zener is 5.5 times faster, and the switch must withstand 36.8 V.
A clamp instead of a diode overheats with frequent switching. It burns more energy than was stored: 50.2 µJ versus 45.0 — at every turn-off.
An analog input catches edges of a neighbouring power circuit. The return loop is large: without ground at 10 mm — 23.5 mV, with ground 0.2 mm below — 0.0320 mV. Return right under the signal, short loops.
A slot in ground under a fast trace. The return current goes around the slot, the loop grows and with it the inductance and crosstalk (section 130.2).
An inductor "suddenly" heats up and whines under load. Peak current above the saturation current: inductance has dropped, ripple has grown (58.2).
A magnetometer is wrong near a power wire. 1 A at 1 cm is 20.0 µT, comparable to the Earth's field. Supply and return wires together (99г.6).
49б.8 Summary
- Current creates a field: a 1 A wire at 1 cm — 20.0 µT, a 5 mm radius turn — 126 µT, a 100-turn coil over 20 mm at 0.1 A — 0.628 mT; μ₀ = 1.25663706127·10⁻⁶ H/m.
L = N·Φ/I: a 100-turn coil on 10 mm — 39.8 µH (Wheeler — 40.2, the long-coil formula — 24 % more); a 100 mH relay coil at 30 mA stores 45.0 µJ.- A loop on the board: 50 × 20 mm — 153 nH, 50 × 2 mm — 73.4 nH; a trace over ground — 7.75 nH/cm (1.5 mm) and 3.81 nH/cm (0.2 mm).
U = L·dI/dt: 20 mA in 5 ns over 50 mm — 155 mV with ground 1.5 mm below and 614 mV without ground.- The spike without protection — 949 V; with a diode — 12.8 V and 0.476 ms; with a diode and a 24 V zener — 36.8 V and 0.0864 ms; ngspice and Python agree.
- Coupling of coaxial 10 mm turns: 0.48 at 1 mm, 0.080 at 10 mm; leakage
L1·(1 − k²)— 19.9 µH at k = 0.99 and 1 mH. - Magnetic crosstalk at 1 mm spacing: 46.1 mV with ground 1.5 mm below, 2.97 mV with 0.2 mm, 95.0 mV without ground.
- A gap keeps an inductor out of saturation: 10.1 µH and 5.97 A in the arbitrary example. Copper skin depth: 66.1 µm at 1 MHz, 6.61 µm at 100 MHz.
Next: section 49в "Waves and transmission lines: signal speed, when a trace becomes a line, reflections, termination, radiation" — the third section of the series "Physics for the developer": why a trace has a speed and a characteristic impedance, when an STM32 pin edge turns it into a line, where ringing on a clock input comes from, why a 22–33 Ω resistor sits at the pin and how a current loop radiates the harmonics of edges.